4.2 - ROOF GARDEN INSULATED CURRENT SECTION
  1. Support treated with Primer V70
  2. NB polymer modified bitumen underlayer membrane
  3. NB bitumen membrane corner strengthening strip
  4. 4 mm Iter Anti-root
  5. Doubling corner made with 4 mm Iter Anti-root
  6. Geocomposite drainage element
  7. Heat insulating element in XPS
  8. Polyester "Non-woven fabric" filtering geotextile
  9. Metallic perimeter protection flashing with mechanical fitting
  10. Sealing
  11. Growth medium

Alternatively:

  1. Wall coping cover
4.2 - ROOF GARDEN
INSULATED CURRENT SECTION,